5 resultados para AMERICAN-HEART-ASSOCIATION

em Digital Commons at Florida International University


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is projected that by 2020, there will be 138 million Americans over 45, the age at which the increased incidence of heart diseases is documented. Many will require stents. This multi-billion dollar industry, with over 2 million patients worldwide, 15% of whom use Nitinol stents have experienced a decline in sales recently, due in part to thrombosis. It is a sudden blood clot that forms inside stents. As a result, the Food and Drug Administration and American Heart Association are calling for a new generation of stents, new designs and different alloys that are more adaptable to the arteries. The future of Nitinol therefore depends on a better understanding of the mechanisms by which Nitinol surfaces can be rendered stable and inert. In this investigation, binary and ternary Nitinol alloys were prepared and subjected to various surface treatments such as electropolishing (EP), magnetoelectropolishing (MEP) and water boiling & passivation (W&P). In vitro corrosion tests were conducted on Nitinol alloys in accordance with ASTM F 2129-08. The metal ions released into the electrolyte during corrosion tests were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). Biocompatibility was assessed by observing the growth of human umbilical vein endothelial cells (HUVEC) on the surface of Nitinol alloys. Static and dynamic immersion tests were performed by immersing the Nitinol alloys in cell culture media and measuring the amount of metal ions released in solution. Sulforhodamine B (SRB) assays were performed to elucidate the effect of metal ions on the growth of HUVEC cells. The surfaces of the alloys were studied using Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS) respectively. Finally, wettability and surface energy were measured by Contact Angle Meter, whereas surface roughness was measured by Atomic Force Microscopy (AFM). All the surface treated alloys exhibited high resistance to corrosion when compared with untreated alloys. SRB assays revealed that Ni and Cu ions exhibited greater toxicity than Cr, Ta and Ti ions on HUVEC cells. EP and MEP alloys possessed relatively smooth surfaces and some were composed of nickel oxides instead of elemental nickel as determined by XPS. MEP exhibited lowest surface energy and lowest surface roughness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context The internet is gaining popularity as a means of delivering employee-based cardiovascular (CV) wellness interventions though little is known about the cardiovascular health outcomes of these programs. In this review, we examined the effectiveness of internet-based employee cardiovascular wellness and prevention programs. Evidence Acquisition We conducted a systematic review by searching PubMed, Web of Science and Cochrane library for all published studies on internet-based programs aimed at improving CV health among employees up to November 2012. We grouped the outcomes according to the American Heart Association (AHA) indicators of cardiovascular wellbeing – weight, BP, lipids, smoking, physical activity, diet, and blood glucose. Evidence Synthesis A total of 18 randomized trials and 11 follow-up studies met our inclusion/exclusion criteria. Follow-up duration ranged from 6 – 24 months. There were significant differences in intervention types and number of components in each intervention. Modest improvements were observed in more than half of the studies with weight related outcomes while no improvement was seen in virtually all the studies with physical activity outcome. In general, internet-based programs were more successful if the interventions also included some physical contact and environmental modification, and if they were targeted at specific disease entities such as hypertension. Only a few of the studies were conducted in persons at-risk for CVD, none in blue-collar workers or low-income earners. Conclusion Internet based programs hold promise for improving the cardiovascular wellness among employees however much work is required to fully understand its utility and long term impact especially in special/at-risk populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is projected that by 2020, there will be 138 million Americans over 45, the age at which the increased incidence of heart diseases is documented. Many will require stents. This multi-billion dollar industry, with over 2 million patients worldwide, 15% of whom use Nitinol stents have experienced a decline in sales recently, due in part to thrombosis. It is a sudden blood clot that forms inside stents. As a result, the Food and Drug Administration and American Heart Association are calling for a new generation of stents, new designs and different alloys that are more adaptable to the arteries. The future of Nitinol therefore depends on a better understanding of the mechanisms by which Nitinol surfaces can be rendered stable and inert. In this investigation, binary and ternary Nitinol alloys were prepared and subjected to various surface treatments such as electropolishing (EP), magnetoelectropolishing (MEP) and water boiling & passivation (W&P). In vitro corrosion tests were conducted on Nitinol alloys in accordance with ASTM F 2129-08. The metal ions released into the electrolyte during corrosion tests were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). Biocompatibility was assessed by observing the growth of human umbilical vein endothelial cells (HUVEC) on the surface of Nitinol alloys. Static and dynamic immersion tests were performed by immersing the Nitinol alloys in cell culture media and measuring the amount of metal ions released in solution. Sulforhodamine B (SRB) assays were performed to elucidate the effect of metal ions on the growth of HUVEC cells. The surfaces of the alloys were studied using Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS) respectively. Finally, wettability and surface energy were measured by Contact Angle Meter, whereas surface roughness was measured by Atomic Force Microscopy (AFM). All the surface treated alloys exhibited high resistance to corrosion when compared with untreated alloys. SRB assays revealed that Ni and Cu ions exhibited greater toxicity than Cr, Ta and Ti ions on HUVEC cells. EP and MEP alloys possessed relatively smooth surfaces and some were composed of nickel oxides instead of elemental nickel as determined by XPS. MEP exhibited lowest surface energy and lowest surface roughness.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Athletic training is an allied health profession recognized by the American Medical Association requiring certification by examination. There are two routes towards certification as an athletic trainer: attending a university with an accredited athletic training program or with an internship program By 2004, the only route towards certification will be by attending a Commission on Accreditation of Allied Health Education Programs (CAAHEP) or National Athletic Trainers' Association (NATA) accredited athletic training program. CAAHEP looks at passing rates on the NATA Board of Certification (NATABOC) examination when granting accreditation. This study examined characteristics of programs associated with first time passing rates. ^ Directors from 39 CAAHEP or NATA accredited athletic training programs completed a descriptive 17-question survey regarding academic characteristics, faculty characteristics, and program characteristics. Analysis used Spearman's rho correlation coefficient, with significance of p = <.05. Four program directors were interviewed to gather additional insight. ^ There were three program characteristics that showed a significant positive association with first attempt passing rates: the number of full-time and part-time approved clinical instructors (ACIs), and the number of students in the program. Further investigation found a statistically significant association between a low ratio of ACIs to athletic training students and first time passing rates. ACIs are certified athletic trainers (ATCs) who have received special training in order to supervise athletic training students. CAAHEP mandates a 1:8 ratio of ATCs to athletic training student. This study showed that a smaller ratio of ATC to student in combination with ACI training was significantly associated with higher first time passing rates. The number of courses above the required 13 delineated by the Education Council showed a significant negative association with first attempt passing rates. ^ Universities seeking or maintaining accreditation should incorporate characteristics associated with a higher passing rate on the NATABOC examination. Characteristics include utilizing a large number of full-time and part-time ACIs, admitting a large number of students into the program while maintaining a low ACI to athletic training student ratio, and offering curricula that focuses on the 13 courses that have been deemed relevant to the athletic training curriculum by the Education Council. ^